VU
Virtual University of Pakistan
Federal Government University

General

  1. The facilities allocated to VU/ building shall be exclusively dedicated and will not be used for any other purpose. 
     
  2. The institution/ building should be located in an easily accessible area. 
     
  3. The location, building and outlook should be well suited for the purpose of higher education. 
     
  4. Properly finished and maintained exterior and interiors. 
     
  5. Parking facilities should be available in the vicinity.

Specific (minimum requirements)

  1. . Covered area of at least 2000 Sq. ft. of usable space, excluding staircases, washrooms, lobbies, parking space etc.

  2. Air-conditioned computer lab(s)

  3. Dedicated Server room(s)

  4. Adequate space for generator and UPS

  5. Dedicated lecture viewing area

  6. Student discussion room(s) with adequate furniture & white board

  7. Common room(s) / waiting room(s) for female students

  8. Separate washrooms for male and female students

Sr.# Item Specifications Requirements

1

Computer Lab(s)

 Preferably big hall(s) instead of small rooms.

 Well ventilated and Air Conditioned.

2

 Desktop PC Specifications

Minimum Specifications with at least Windows 10 Operating System

Intel Corei3 (6th Generation) RAM=4GB DDR-4 (Preferably 8GB) HDD=320GB or higher

OR

HDD=SSD 128GB or higher

Recommended Specifications
(For atleast 4-5 years road map)

Intel Corei5 (6th Generation) or higher RAM=8GB DDR-4 HDD=SSD 256GB or higher for better performance.

 A certain Ratio between Number of PCs and total enrolled student strength must be maintained which will be communicated from time to time. Initially 30 computers lab is required for qualifying for PVC of Virtual University of Pakistan.

3

 Servers Specifications

Minimum Specifications with latest Windows Server Operating System

Intel Corei5 (6th Generation)
RAM=8GB DDR-4 (Preferably 16GB)
HDD=500GB or higher

AND

HDD=1 x 4TB for lecture server only.

Recommended Specifications
(For atleast 4-5 years road map)

Intel Corei5 (6th Generation) or higher
RAM= 16GB DDR-4
HDD= 256GB SSD or higher for better performance.

OR

HDD=1TB or higher.

AND

HDD=1 x 4TB for lecture server only.

 
 
 
 
Total Servers = 03
 
 
1 Active Directory,
DNS,
DHCP,
RRAS
 
 
 
2 Exam Server.
 
 
 
 
 
3 Active Directory,
DNS,
DHCP,
RRAS

& Exam Server.
 

4

 Display

Minimum Specifications

LED\LCD (Widescreen) = 17” - 19” (Preferably 19”)

Recommended Specifications or higher

LED\LCD (Widescreen) = 23”

5

 Internet Connection

 Minimum 8-MBs for every 30 computers. Preferably CIR / Dedicated.

Reliable and fast internet connection.

6

 Backup Internet Connection

 Same as Primary

 Same as Primary

7

 Generators

20 kVA generator is recommended for every 30 Computers, 3 Servers, Network Switches, 1 Printer, 1 Scanner, & CCTV Camera system alongwith building load.
Must support all servers, client computers, other IT equipment, A/Cs, building load, and remain in perfect working condition at all times.

8

 UPS

10 kVA UPS is recommended for every 30 Computers, 3 Servers, Network Switches, 1 Printer, 1 Scanner, & CCTV Camera System.
Must support all servers, client computers, other IT equipment, and remain in perfect working condition at all times.

9

 Printer

One Laser printer
Must remain in perfect working condition at all times.

10

 Scanner

With resolution of 1200 dpi, 48-bit color
Must remain in perfect working condition at all times.

11

 Shields

Cover for all monitors
All monitors must have shield covers.

12

 CCTV Camera

NVR/IP based CCTV cameras must be installed at entrance and computer lab(s) with capacity to hold at least fifteen days recording.

13

 Network Infrastructure

Gigabit network must be installed with proper termination using keystone jack (I/O). Switches must be installed in Network cabinet. Network cables must be terminated in network cabinet using patch panel and tagged properly. Cable manager should be used for termination from Patch Panel to Network Switch. Network cables should be in ducts.

14

 Anti-Virus

Mandatory
Updated Antivirus on servers and all client computers.

15

 Air Conditioners

Air Conditioners must be installed to maintain comfortable temperature in all computers labs & server room and supported by the generator.

16

 Networking Staff

Qualification: BS (CS/IT) (OR) BE (EE) (at least 2nd division) from HEC recognized University / Institution. Experience & Skills: Must be experienced in System/Network administration. Internationally acclaimed valid Network Certification will be preferred.

        In case PVC is nominated as Exam Center, one additional server will be required.

        Note: The University reserves the right to revise and upgrade the requirements from time to time

Browse Back