Sr.#
|
Item
|
Specifications
|
Requirements
|
1
|
Computer Lab(s)
|
Preferably big hall(s) instead of small rooms.
|
Well ventilated and Air Conditioned.
|
2
|
Desktop PC Specifications
|
Minimum Specifications with at least Windows 10 Operating System
Intel Corei3 (6th Generation) RAM=4GB DDR-4 (Preferably 8GB) HDD=320GB or higher
OR
HDD=SSD 128GB or higher
Recommended Specifications
(For atleast 4-5 years road map)
Intel Corei5 (6th Generation) or higher RAM=8GB DDR-4 HDD=SSD 256GB or higher for better performance.
|
|
A certain Ratio between Number of PCs and total enrolled student strength must be maintained which will be communicated from time to time. Initially 30 computers lab is required for qualifying for PVC of Virtual University of Pakistan.
|
3
|
Servers Specifications
|
Minimum Specifications with latest Windows Server Operating System
Intel Corei5 (6th Generation)
RAM=8GB DDR-4 (Preferably 16GB)
HDD=500GB or higher
AND
HDD=1 x 4TB for lecture server only.
Recommended Specifications
(For atleast 4-5 years road map)
Intel Corei5 (6th Generation) or higher
RAM= 16GB DDR-4
HDD= 256GB SSD or higher for better performance.
OR
HDD=1TB or higher.
AND
HDD=1 x 4TB for lecture server only.
|
|
|
|
|
Total Servers = 03
|
|
|
1
|
Active Directory, DNS, DHCP, RRAS
|
|
|
|
2
|
Exam Server.
|
|
|
|
|
|
3
|
Active Directory, DNS, DHCP, RRAS
& Exam Server.
|
|
|
4
|
Display
|
Minimum Specifications
LED\LCD (Widescreen) = 17” - 19” (Preferably 19”)
Recommended Specifications or higher
LED\LCD (Widescreen) = 23”
|
|
5
|
Internet Connection
|
Minimum 8-MBs for every 30 computers. Preferably CIR / Dedicated.
|
Reliable and fast internet connection.
|
6
|
Backup Internet Connection
|
Same as Primary
|
Same as Primary
|
7
|
Generators
|
20 kVA generator is recommended for every 30 Computers, 3 Servers, Network Switches, 1 Printer, 1 Scanner, & CCTV Camera system alongwith building load.
|
|
Must support all servers, client computers, other IT equipment, A/Cs, building load, and remain in perfect working condition at all times.
|
|
8
|
UPS
|
10 kVA UPS is recommended for every 30 Computers, 3 Servers, Network Switches, 1 Printer, 1 Scanner, & CCTV Camera System.
|
|
Must support all servers, client computers, other IT equipment, and remain in perfect working condition at all times.
|
|
9
|
Printer
|
|
Must remain in perfect working condition at all times.
|
|
10
|
Scanner
|
With resolution of 1200 dpi, 48-bit color
|
|
Must remain in perfect working condition at all times.
|
|
11
|
Shields
|
|
All monitors must have shield covers.
|
|
12
|
CCTV Camera
|
NVR/IP based CCTV cameras must be installed at entrance and computer lab(s) with capacity to hold at least fifteen days recording.
|
|
13
|
Network Infrastructure
|
Gigabit network must be installed with proper termination using keystone jack (I/O). Switches must be installed in Network cabinet. Network cables must be terminated in network cabinet using patch panel and tagged properly. Cable manager should be used for termination from Patch Panel to Network Switch. Network cables should be in ducts.
|
|
14
|
Anti-Virus
|
|
Updated Antivirus on servers and all client computers.
|
|
15
|
Air Conditioners
|
Air Conditioners must be installed to maintain comfortable temperature in all computers labs & server room and supported by the generator.
|
|
16
|
Networking Staff
|
Qualification: BS (CS/IT) (OR) BE (EE) (at least 2nd division) from HEC recognized University / Institution. Experience & Skills: Must be experienced in System/Network administration. Internationally acclaimed valid Network Certification will be preferred.
|
|